Ajax TOCCO Toccotron AC Dokumentacja Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 20
OM-229 158 Page 17
804 597-A
4-11. I/O Receptacle RC13 Information And Connections
1. Plug
2. Threaded Collar
3. I/O Receptacle RC13 (See
Section 4-12)
To connect to receptacle, insert
plug and tighten threaded collar.
3
2
1
4-12. I/O Receptacle RC13 Socket Information
Socket No. Socket Information
1 Incycle Common
2 Incycle Normally Closed
3 Incycle Normally Open
4 Auxiliary Common
5 Auxiliary Normally Closed
6 Auxiliary Normally Open
7 Limit Common
8 Limit Normally Closed
9 Limit Normally Open
10 Not Used
11
External Interrupt This works like an interlock (if enabled via the setup screens). This could
be used as a coolant flow switch or for other purposes.
12 +24 volts DC
13 +24 volts DC
14 Remote Enable This is the external contact closure to enable output when in Remote mode.
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 51 52

Komentarze do niniejszej Instrukcji